Troubleshooting the WT6300
Troubleshooting the WT6300

Troubleshooting the WT6300

This table describes problems, causes, and solutions to troubleshooting the device.
Troubleshooting the WT6300
Problem
Cause
Solution
Device does not turn on.
Battery not charged.
Charge or replace the battery in the device.
Battery not installed properly.
Ensure battery is installed properly. See Installing the Battery.
System crash.
Perform a soft reset. If the device still does not turn on, perform a hard reset.
Battery did not charge.
Battery failed.
Replace battery. If the device still does not operate, try a soft reset, then a hard reset.
Device removed from cradle before charging completed.
Insert the device into the cradle and begin charging. The battery fully charges in approximately four hours.
Ambient temperature of the cradle is too warm or too cold.
The ambient temperature must be between 0°C and 40°C (32 °F and 104°F).
During data communication, no data was transmitted, or transmitted data was incomplete.
Device unplugged from host computer during communication.
Reconnect the programming cable to the host computer and re-transmit.
Communication software was incorrectly installed or configured.
See system administrator.
Device turns itself off.
Device is inactive.
The device turns off after a period of inactivity. If the device is running on battery power, this period can be set to 15 seconds, 30 seconds, 1 minute, 2 minutes, 5 minutes, 10 minutes, or 30 minutes.
Change the setting if you need a longer delay before the automatic shutoff feature activates.
Battery is depleted.
Place the device in the cradle to re-charge the battery.
Battery is not inserted properly.
Insert the battery properly. See Installing the Battery.
The devices' battery is low and it powers down to protect memory content.
Place the device in the cradle to re-charge the battery.
A message appears stating that the devices’ memory is full.
Too many files stored on the device.
Delete unused memos and records. You can save these records on the host computer.
Too many applications installed on the device.
If you have installed additional applications on the device, remove them to recover memory.
The device does not accept scan input from optional scanner.
Unreadable bar code.
Ensure the symbol is not defaced.
Distance between scanner exit window and bar code is incorrect.
Move the scanner closer or further from the bar code to the proper scanning range.
Device is not programmed for the bar code.
Verify that the device can read the type of bar code being scanned. Ensure that the bar code parameters are set properly for the bar code being scanned.
Device is not programmed to generate a beep.
Verify that a beep on a good decode is used.
During USB data communications, no data was transmitted, or transmitted data was incomplete.
Incorrect cable connection.
See the Accessories section.
Communications software is not installed or configured properly.
Perform setup as described in the Accessories section.