Define the pulse width of the signal to trigger a device over the input of your choice.
Navigate to the
Configuration
screen using the left menu on the
Home
screen.
In the top left
GPIO
section, select the desired trigger pin (either In 0 or In 1), and click
Update
.
Click
Config
to edit the
Trigger Pulse
and
Pass/Fail Pulse
fields.
Enter the desired values and click
Update
.
Trigger Pulse: specifies the pulse width for the signal that triggers the follower devices.
Pass/Fail Pulse: specifies the pulse width for the pass/fail result signal.
If you configure the same output for GPIO Pass/Fail and as an input for the follower device (for example, trigger input), the trigger input for the follower device takes precedence.
When configuring followers to receive triggers on either Out0 or Out1, updating the trigger input for each follower in the Connectivity Gateway is required. Review your wiring to ensure it matches the GS20 pinout and determine which pin the follower devices should connect to.
The Connectivity Gateway supports the configuration of all followers to one Out pin (up to 16 devices) or splitting them between Out0 and Out1. If you decide to split the followers between outputs, you are unable to output the GPIO Pass/Fail result.