Item | Description |
---|---|
Physical and Environmental Characteristics | |
Dimensions | 335 mm x 254 mm x 73.8 mm (13.2 in. x 10.0 in. x 2.9 in.) with the RFID antenna and mounting bracket. 291 mm x 254 mm x 70.8 mm (11.5 in. x 10.0 in. x 2.8 in.) with the RFID antenna and without the mounting bracket. 335 mm x 254 mm x 55 mm (13.2 in. x 10.0 in. x 2.2 in.) for models with the bracket and without the RFID antenna. 291 mm x 254 mm x 52 mm (11.5 in. x 10.0 in. x 2.0 in.) for models with neither the bracket nor antenna. |
Weight | 2.70 kg (5.95 lbs) 8 Port with Mounting Bracket
2.50 kg (5.50 lbs) 8 Port without Mounting Bracket 3.07 kg (6.75 lbs) Integrated Antenna with 4 External RP-TNC Antenna Ports without Mounting Bracket 2.86 kg (6.30 lbs) Integrated Antenna with 4 External RP-TNC Antenna Ports with Mounting Bracket |
Base Material | Die-cast aluminum and plastic |
Visual Status Indicators | Multi-color LEDs: Power, Activity, Status, Application, Ethernet, Wi-FI, WAN (4G/5G), and Bluetooth |
Mounting | Flush Mount Brackets and Articulating VESA Mount for Wall or Pole Mounting. |
Environmental Specifications | |
Operational Temperature | -40° to +65° C/ -40° to +149° F |
Storage Temperature | -40° to +70° C/ -40° to + 158° F |
Humidity | 5% - 95% relative humidity non-condensing |
Ingress Protection | IP65 and IP67 |
Vibration | MIL STD 810 Method 514, Procedure I- Random .04g2/Hz (20 Hz to 2000 Hz), 6 grms- Sine sweep 4g peak, 5Hz to 2 kHz |
Altitude | MIL STD 810 Method 500 |
Solar Radiation | IEC 60068-2-5 Procedure A |
Salt Fog | MIL STD 810H Method 509.7 |
ESD | |
Connectivity | |
Communications | 10/100/1000 BaseT Ethernet (M12 Connector) w/ PoE support, PoE+, USB Client, USB Host(x2)(M12 Connector) |
General Purpose I/O | 4 GPI/4GPO Optically Isolated
Aux Voltage Output up to 1A 12 Pin M12 A-Coded Connector |
Power | DC Input (12V to 24V, M12 DC Input Connector) PoE(802.3af), PoE+ (802.3at)(M12 Ethernet Connector) 24Vdc,3.25A PoE 55V |
Antenna Ports | FXR90-4: 4 mono-static ports (reverse polarity TNC) FXR90-4: Integrated Antenna with 4 External RP-TNC Antenna Ports FXR90-8: 8 mono-static ports (reverse polarity TNC) |
Hardware/OS and Firmware Management | |
Memory | Flash 16GB EMMC; LPDDR4 2GB |
Operating System | Linux |
Firmware Upgrade | Web-based and remote firmware upgrade capabilities |
Network Services | DHCP, HTTPS, SFTP, SSH, and NTP |
Network Slack | IPv4, IPv6 |
Security | Transport Layer Security Ver. 1.3, FIPS 140-2 Level 1 |
Air Protocols | EPCglobal UHF Class 1 Gen2, ISO/IEC 18000-63 |
Frequency (UHF Band) | Global Reader: 902 MHz to 928 MHz (Maximum, supports countries that use a part of this band) 865 MHz to 868 MHz |
Transmit Power Output | 0dBm to +33dBm (PoE+,802.3at), DC Input) |
Max Receive Sensitivity | -92 dBm RFID receive sensitivity |
IP Addressing | Static and Dynamic |
Warranty | |
For the complete Zebra hardware product warranty statement, go to: zebra.com/warranty. | |
Recommended Services | |
Support Services | Zebra One Care Select and Zebra One Care On-Site |
Advanced Services | RFID Design and Deployment Services |