4-Slot Battery Charger

4-Slot Battery Charger

Troubleshooting the 4-Slot Battery Charger
Symptom
Possible Cause
Action
Spare Battery not charging.
Charger is not receiving power.
Ensure the power cable is connected securely to both the charger and to AC power.
Spare battery is not correctly seated.
Remove and re-insert the battery into the battery adapter, ensuring it is correctly seated.
Battery adapter is not seated properly.
Remove and re-insert the battery adapter into the charger, ensuring it is correctly seated.
Battery was removed from the charger or charger was unplugged from AC power too soon.
Ensure charger is receiving power. Ensure the spare battery is seated correctly. The standard or high-capacity spare battery charges from fully depleted to 90% in approximately 3 hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
Ambient temperature of the cradle is too warm.
Move the cradle to an area where the ambient temperature is between 2°C and 46°C (35.6°F and 114.8°F).
Spare Battery Charging LED does not light when spare battery is inserted.
Spare battery is not correctly seated.
Remove and re-insert the spare battery into the charging slot, ensuring it is correctly seated.