1-Slot PD Charging Cradle Troubleshooting

1-Slot PD Charging Cradle Troubleshooting

This section provides troubleshooting options for charge only cradles.
Troubleshooting the 1-Slot PD Charging Cradle
Symptom
Possible Cause
Solution
Battery is not charging.
Device was removed from cradle or cradle was unplugged from AC power.
Ensure cradle is receiving power. Ensure device is seated correctly. Confirm main battery is charging. The battery fully charges in approximately four hours.
Battery is faulty.
Verify that other batteries charge properly. If so, replace the faulty battery.
The device is not fully seated in the cradle.
Remove and re-insert the device into the cradle, ensuring it is firmly seated.
Ambient temperature of the cradle is too warm or too cold.
Move the cradle to an area where the ambient temperature is between 0°C and 40°C (32°F and 104°F).