This command determines the port that should be monitored
for user data. This allows the user to attach an external device,
such as a keyboard or barcode scanner, and have input captured into
the
capture.channel1.data.raw
command. Once the
data is in the SGD they can use it as they would any other SGD (this includes
functionality that allows users to be sent an alert when an SGD
value changes).
The data received on the specified port will
be read until the value in
capture.channel1.delimiter
is
seen, at which point the data received until (but not including)
the delimiter will be stored in
capture.channel1.data.raw
.
For
the port specified in
capture.channel1.port
, no
data will be sent to any of the parsers on that port. All data received
is assumed to be user input that is to be placed in
capture.channel1.data.raw
.
To disable the data capture functionality, set
capture.channel1.port
to
"off"
The
delimiter will not be stored in
capture.channel1.data.raw
.
The port will be shown in the data capture portion of the HZA response.
The capture port shall be defaulted to
“off”
by
any mechanism (including
^JUF, ^JUA
, and
device.restore_defaults
).
Setvar
To set the port to be monitored
for user data:
! U1 setvar "capture.channel1.port" "value"
Values
off
means no data is stored in
capture.channel1.data.raw
and
all data is sent to the parsers - normal operation
serial
means data is read off the serial port.
No data sent to the parsers on this port.
usb
means ata is read off the USB port. No
data sent to the parsers on this port.
bt
means data is read off the Bluetooth
®
port.
No data sent to the parsers on this port.
usb_host
is not yet supported. Reserved for
when usb host is implemented.
Default
"off"
Getvar
To retrieve the printer’s current
port being monitored for user data: