Parameter | Details |
|---|---|
query-type
| For detailed examples of these parameters, see ~HQ Examples.
Values:
Default:
must be an accepted value or the command is ignored |
Error Flags | Flag | Group 2 | Group 1 (X = Value can be any hexadecimal number [0-9, A-F]) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
Nibbles 16-9 | Nibble 8 | Nibble 7 | Nibble 6 | Nibble 5 | Nibble 4 | Nibble 3 | Nibble 2 | Nibble 1 | ||
No Error | 0 | 00000000 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Error Present | 1 | 00000000 | X | X | X | X | X | X | X | X |
Printhead Thermistor Open | 1 | 00000000 | X | X | X | X | X | 2 | X | X |
Invalid Firmware Config. | 1 | 00000000 | X | X | X | X | X | 1 | X | X |
Printhead Detection Error | 1 | 00000000 | X | X | X | X | X | X | 8 | X |
Bad Printhead Element | 1 | 00000000 | X | X | X | X | X | X | 4 | X |
Motor Over Temperature | 1 | 00000000 | X | X | X | X | X | X | 2 | X |
Printhead Over Temperature | 1 | 00000000 | X | X | X | X | X | X | 1 | X |
Cutter Fault | 1 | 00000000 | X | X | X | X | X | X | X | 8 |
Head Open | 1 | 00000000 | X | X | X | X | X | X | X | 4 |
Ribbon Out | 1 | 00000000 | X | X | X | X | X | X | X | 2 |
Media Out | 1 | 00000000 | X | X | X | X | X | X | X | 1 |
Clear Paper Path Failed
1
| 1 | 00000000 | X | X | X | X | 8 | X | X | X |
Paper Feed Error
1
| 1 | 00000000 | X | X | X | X | 4 | X | X | X |
Presenter Not Running
1
| 1 | 00000000 | X | X | X | X | 2 | X | X | X |
Paper Jam during Retract
1
| 1 | 00000000 | X | X | X | X | 1 | X | X | X |
Black Mark not Found
1
| 1 | 00000000 | X | X | X | 8 | X | X | X | X |
Black Mark Calibrate Error
1
| 1 | 00000000 | X | X | X | 4 | X | X | X | X |
Retract Function timed out
1
| 1 | 00000000 | X | X | X | 2 | X | X | X | X |
Paused | 1 | 00000000 | X | X | X | 1 | X | X | X | X |
Error Flags | Flag | Group 2 | Group 1 (X = Value can be any hexadecimal number [0-9, A-F]) | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
Nibbles 16-9 | Nibble 8 | Nibble 7 | Nibble 6 | Nibble 5 | Nibble 4 | Nibble 3 | Nibble 2 | Nibble 1 | ||
No Warning | 0 | 00000000 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Warning Present | 1 | 00000000 | X | X | X | X | X | X | X | X |
Paper-near-end Sensor
1
| 1 | 00000000 | X | X | X | X | X | X | X | 8 |
Replace Printhead | 1 | 00000000 | X | X | X | X | X | X | X | 4 |
Clean Printhead | 1 | 00000000 | X | X | X | X | X | X | X | 2 |
Need to Calibrate Media | 1 | 00000000 | X | X | X | X | X | X | X | 1 |
Sensor 1 (Paper before head)
1
| 1 | 00000000 | X | X | X | X | X | X | 1 | X |
Sensor 2 (Black mark)
1
| 1 | 00000000 | X | X | X | X | X | X | 2 | X |
Sensor 3 (Paper after head)
1
| 1 | 00000000 | X | X | X | X | X | X | 4 | X |
Sensor 4 (loop ready)
1
| 1 | 00000000 | X | X | X | X | X | X | 8 | X |
Sensor 5 (presenter)
1
| 1 | 00000000 | X | X | X | X | X | 1 | X | X |
Sensor 6 (retract ready)
1
| 1 | 00000000 | X | X | X | X | X | 2 | X | X |
Sensor 7 (in retract)
1
| 1 | 00000000 | X | X | X | X | X | 4 | X | X |
Sensor 8 (at bin)
1
| 1 | 00000000 | X | X | X | X | X | 8 | X | X |
PRINTER STATUS
ERRORS: 1 00000000 00000005
WARNINGS: 1 00000000 00000002
1 | Flag |
2 | Nibble 16-9 |
3 | Nibble 8-4 |
4 | Nibble 3 |
5 | Nibble 2 |
6 | Nibble 1 |
PRINTER STATUS
ERRORS: 1 00000000 0000000B
WARNINGS: 0 00000000 00000000
MAC ADDRESS
00:07:4d:2c:e0:7a
PRINT HEAD TEST RESULTS
0,A,0000,0000,0000
PRINT HEAD TEST RESULTS:
0,A,0015,0367,0000
1 | Element failure |
2 | Manual (M) or automatic (A) range |
3 | First test element |
4 | Last test element |
5 | Failure count |
~HQMA
MAINTENANCE ALERT SETTINGS
HEAD REPLACEMENT INTERVAL: 1 km
HEAD REPLACEMENT FREQUENCY: 0 M
HEAD CLEANING INTERVAL: 0 M
HEAD CLEANING FREQUENCY: 0 M
PRINT REPLACEMENT ALERT: NO
PRINT CLEANING ALERT: NO
UNITS: C
MAINTENANCE ALERT MESSAGES
CLEAN: PLEASE CLEAN PRINT HEAD
REPLACE: PLEASE REPLACE PRINT HEAD
PRINT METERS
TOTAL NONRESETTABLE: 8560 "
USER RESETTABLE CNTR1: 9 "
USER RESETTABLE CNTR2: 8560 "
^XA^MA,,,,C
^XZ
PRINT METERS
TOTAL NONRESETTABLE: 21744 cm
USER RESETTABLE CNTR1: 24 cm
USER RESETTABLE CNTR2: 21744 cm
LAST CLEANED: 257 "
HEAD LIFE HISTORY
# DISTANCE
1: 257 "
2: 1489 "
3: 7070 "
line 1 | The current life of the print head. |
lines 2–10 | Tracks the measurement for each time the print head is changed. (The example only shows lines 2 and 3.) |
PLUG AND PLAY MESSAGES
MFG: Zebra Technologies
CMD: ZPL
MDL: GX420t
SERIAL NUMBER
41A06440023
USB INFORMATION
PID: 0085
RELEASE VERSION: 15.01