Parameters | Details |
|---|---|
o =
orientation | Values:
N =
normalR =
rotated 90 degrees (clockwise)I =
inverted 180 degreesB =
read from the bottom up, 270 degreesDefault:
N
|
h =
bar code height for individual rows (in dots) | Values:
2
to
32000
Default:
8
This number, multiplied by the module, equals the height of the individual row in dots. |
s =
security level | Values:
N =
no Y =
yes Default:
Y
Security level determines whether symbol check-sums are generated and added to the symbol. Checksums are never generated for single-row symbols. This can be turned off only if the parameter
m
is set to
A
. |
c =
number of characters per row (data columns) | Values:
2
to
62
characters |
r =
number of rows to encode- | Values:
for CODABLOCK A:
1
to
22
for CODABLOCK E and F:
2
to
4
|
m =
mode | Values:
A
,
E
,
F
CODABLOCK A uses the Code 39 character set.
CODABLOCK F uses the Code 128 character set.
CODABLOCK E uses the Code 128 character set and automatically adds FNC1.
Default:
F
|
<fnc1> = 80 hex
| <fnc3> = 82 hex
|
<fnc2> = 81 hex
| <fnc4> = 83 hex
|
<nul> = 84 hex
|
<fnc1> = 80 hex
| <fnc3> = 82 hex
|
<fnc2> = 81 hex
| <fnc4> = 83 hex
|
<nul> = 84 hex
|