This parameter controls the antenna's RF power when operated in presentation (hands-free) mode. The following tables list the levels and the associated range as a percent of the baseline range.
The baseline range is the range that results when the power level is set to a maximum level of eight, and varies depending on the environment, tag sensitivity, and orientation.
Corded Scanner Antenna Power (dBM) in Hands-Free Mode - European Union
Level
Range (% of Baseline)
Horizontal Power (dBm)
Vertical Power (dBm)
1
13%
0.1
0.5
2
25%
2.1
4.0
3
38%
5.1
8.2
4
50%
8.6
10.8
5
63%
11.4
12.9
6
75%
13.6
14.6
7
88%
15.2
16.2
8
100%
16.5
17.7
Cordless Scanner Antenna Power (dBM) in Hands-Free Mode - European Union
Level
Range (% of Baseline)
Horizontal Power (dBm)
Vertical Power (dBm)
1
13%
0.1
0.1
2
25%
5.6
1.4
3
38%
9.3
6.3
4
50%
11.9
8.8
5
63%
14.0
10.8
6
75%
15.9
12.5
7
88%
17.5
14.0
8
100%
19.0
15.3
Corded Scanner Antenna Power (dBM) in Hands-Free Mode - North America
Level
Range (% of Baseline)
Horizontal Power (dBm)
Vertical Power (dBm)
1
13%
2.0
1.4
2
25%
6.0
7.2
3
38%
9.7
11.5
4
50%
12.2
14.2
5
63%
14.3
16.1
6
75%
16.2
17.6
7
88%
17.8
18.9
8
100%
19.4
20.0
Cordless Scanner Antenna Power (dBM) in Hands-Free Mode - North America
Level
Range (% of Baseline)
Horizontal Power (dBm)
Vertical Power (dBm)
1
13%
0.1
1.1
2
25%
5.1
3.6
3
38%
9.2
7.0
4
50%
11.9
10.4
5
63%
13.9
12.9
6
75%
15.6
14.7
7
88%
16.9
16.2
8
100%
18.1
17.4