Solutions
Hardware
Software
Services
Support and Downloads
About Zebra
Zebra Aurora User Guide
Using Fixed Industrial Scanning Tools
Zebra Aurora User Guide
Zebra Aurora User Guide
About this Guide
Icon Conventions
Notational Conventions
Service Information
Minimum PC Requirements
Installation
Localization
Zebra Aurora Software Overview
Zebra Aurora Features
UI Overview
Device Discovery
Setting Up a New Device
Adding Devices via IP Address
Viewing Devices
Network Setup
Configuring Device Settings
General Settings
Communication Settings
Network Settings
TCP/IP Settings
RS-232 Settings
Date/Time Settings
PLC Protocol
USB Settings
GPIO Mapping
Configuring Jobs
Capture
Using the Filmstrip
Build
Barcode Quality Metrics
BQM Best Practices
Connect
Data Formatting
Accessing the Web HMI
Web HMI Dashboard
Live Monitoring with the Web HMI
Viewing Result History
Viewing the Job List
Viewing the Activity Log
Updating Device Firmware
USB-A to USB-C Hardware Setup
Firmware Update
Performing a Factory Reset
Using Fixed Industrial Scanning Tools
Editing and Deploying FS Jobs
Using the Job Toolstrip
Fixed Industrial Scanner Settings
Using BQM for Fixed Scanning Jobs
Advanced
Image Banks
Symbologies
ManyCode
Using Machine Vision Tools
Deploying VS Jobs
Common Machine Vision Tool Settings
Locate Tools
Locate Object
General Locate Object Settings
Advanced Locate Object Settings
Locate Object Plus
Advanced Locate Object Plus Settings
Locate Edge
General Locate Edge Settings
Locate Blob
General Locate Blob Settings
Locate Circle
General Locate Circle Settings
Advanced Locate Circle Settings
Filter Tools
Binarize
Dilate
Erode
Open
Close
Gradient Full
Gradient Horizontal
Gradient Vertical
Identification Tools
Using BQM for Identification Tools
Read Barcode
Read DPM
Read DPM and Barcode
Datacode
Deep Learning OCR
Advanced Deep Learning OCR Settings
Presence/Absence Tools
Object Presence Absence
Advanced Object Presence Absence Settings
Object Plus Presence Absence
Brightness
Contrast
Edge Detect
Blob Presence Absence
Measurement Tools
Distance
Circle Diameter
Measure Object Width
Advanced Measure Object Width Settings
Counting Tools
Pixel Count
Blob Count
Edge Count
Locate Object Count
Advanced Locate Object Count Settings
Flaw Detection
Edges
Intensity
Upgrading a FIS/MV Tools License
Obtaining A License Key
Activating a License with Zebra Aurora
Acquiring a License
License Acquisition Modes
Acquiring an Activation ID
Acquiring a License from the Online Server
Downloading an Offline License from the Server
Acquiring a License by Downloading a Bin File
Downloading the Capability Response
Time Tampering
License Types
Fixed Industrial Scanning Toolset
Machine Vision Toolsets
Connectivity Guidelines
Network Communication
Setting a Static IP Address
Changing the Hostname
TCP/IP Results
Listening for TCP/IP Output Events
TCP/IP Communication
Setting Up TCP/IP Triggering
Enabling TCP/IP Output in Device Settings
Configuring Jobs to Accept TCP/IP Triggers
Sending TCP/IP Triggers to the Device
Setting up RS-232 Triggering
Enabling RS-232 Output in Device Settings
Configuring a Job on the Device to Accept Serial Triggers
Sending a Serial Trigger to the Device
Listening to RS-232 Output Events
USB Settings
Enabling HID Keyboard
Adding a Keystring Delay
PLC Protocol
Troubleshooting
RegEx Overview
RegEx Examples
Using Fixed Industrial Scanning Tools
Using Fixed Industrial Scanning Tools
Editing and Deploying FS Jobs
Using the Job Toolstrip
Fixed Industrial Scanner Settings
Using BQM for Fixed Scanning Jobs
Advanced
Image Banks
Symbologies
ManyCode