Capture

Capture

The Capture chevron configures
Triggers
and
Acquisition Settings
for Fixed Industrial Scanning or Machine Vision jobs.
Trigger Settings
Item
Description
Source
Select the trigger source from GPIO, Device Trigger, Serial, PLC, TCP/IP Auto(Self), Test Trigger
Job Mode
Select the Job Mode between Single Shot, Level Continuous, Series (Burst), Periodic Single Shot, Continuous, Presentation
GPIO Inputs
When the Source trigger is set to GPIO, use this drop-down menu to select the GPIO input. This is useful if more than one GPIO is configured as Input. The number corresponds to the GPIO number, and the description is the current configuration of the GPIO, for example:
  • 0: Rising Edge
  • 1: Rising Edge
  • 4: Falling Edge
Active Job Timeout
This is the maximum duration for the inspection Job
Do Not Read Last
Use this option to skip reading the last barcodes. Typically, presentation mode or continuous mode is used to ensure that codes are decoded twice.
Show Image
Disable this option to speed up the decoding
Acquisition Settings determine the configuration used to capture images with the device.
Acquisition
Setting
Description
Barcode Autotune
Use this button to force an automatic tune procedure that configures the camera to read the barcode or Datamatrix, adjusting.
Exposure
,
Gain Factor
and
Focus
.
Autotune Settings
Open the dialog to adjust the Autotune Settings.
Image Perfect+ Setup
The setup list on the left is the possible configuration for Image Perfect+.
Add Settings
Use this command to add a new setup to Image Perfect+
Name
Assign a name for the Image Acquisition Setup
Exposure
Exposure time in ms.
Long Exposure
Activate this option to adjust the exposure time from 33 to 750 ms.
Gain Factor
Use this slider to adjust the sensor gain factor from 0 to 100.
Focus
Use this slider to adjust the focus length.
Aiming Configuration
Enabling this feature projects an aiming pattern onto the surface where the camera is pointing and helps to position the camera by identifying the focal point of the field of view.
Internal Illumination
This setting can only be enabled with Unrestricted USB Power, PoE, and 24V external power.
Light Intensity
Use the slider to increase light intensity by sliding to the right.
  • Minimum: 1
  • Default: 4
  • Maximum: 10
Red Light
  • Top: enable this setting to use the top illuminator on the device.
  • Bottom: enable this setting to use the bottom illuminator on the device.
  • Right: enable this setting to use the suitable illuminator on the device.
  • Left: enable this setting to use the left illuminator on the device.
External Illumination
External illumination can be activated only when a 24V DC power supply provides the power.
Light Intensity
This controls the analog voltage pin on the Analog Output Pin.
  • Minimum: 1
  • Default: 8
  • Maximum: 10