Parameters | Details |
---|---|
o = operation | Specifies the action to be performed. Values: W = write to (encode) the tagL = write with LOCK (if supported by tag type; Gen 2 tag type does not use this locking function)R = read the tagP = read password (Gen 2 tag type only. Not supported on all Gen 2 printers, including the ZD500R printer.)S = specify the access passwordDefault: W |
f = format | Values: A = ASCIIH = HexadecimalE = EPC (ensure proper setup with the ^RB command)Default: H |
b = passwordORb = starting block number | For Gen 2 tag type only: What you specify for this parameter depends on what you enter for other parameters. When the Gen 2 memory bank parameter is set to E (EPC 96‑bit) or A (EPC and Auto adjust PC bits), W and R values are always set to 2.If the Operation parameter value is... W Values: P , which indicates that an access password, a kill password, or both follow in a ^FD command. Each password must be 8 hex characters. If the password is omitted, it is not written. An access password is used in subsequent lock commands in the format.0 to n, which specifies the 16-bit starting block number, where n is the maximum number of blocks for the bank specified in the memory bank parameter. Default: 0 R Values: 0 to n, which specifies the 16-bit starting block number, where n is the maximum number of blocks for the bank specified in the memory bank parameter. Default: 0 S This parameter must be P and must be followed by the access password in a ^FD command.For tag types other than Gen 2: Specifies the starting block number. Values: 0 to n, where n is the maximum number of blocks for the tag.Default: 0 |
n = number of bytes to read or write | Specifies the number of bytes to read or write. For high-frequency (HF) printers: Values: 1 to n, where n is the maximum number of bytes for the tag.Default: 1For Gen 2 tag type only: When E or A is specified for the memory bank parameter, this value is not required.Values: 1 to n, where n is the maximum number of bytes for the tag.Default: 1For all other printers and tag types: This parameter applies only when the starting block number is 1. Values: 1 to n, where n is the maximum number of bytes for the tag. For UCODE EPC 1.19, n is 32.Default: 1 |
m = Gen 2 memory bank | This parameter applies to Gen 2 tags only. Specifies the Gen 2 memory bank. For more information about Gen 2 memory, refer to the RFID Programming Guide for your printer. E = EPC 96-bit (When writing data, this parameter performs the operation on Gen 2 bit address 20h and accesses 12 bytes of the EPC memory bank. When reading data, this parameter reads the amount of data specified in the PC bits on the tag.)A = EPC and Auto adjust PC bits (When writing data, this parameter performs the operation on Gen 2 bit address 20h of the EPC memory bank and accesses the number of bytes specified in the ^FD . The PC bits will be updated to match the amount of data written to the tag. When reading data, this parameter reads the amount of data specified in the PC bits on the tag.This value is supported only by the ZD500R printer and ZT400 Series and ZT600_Series RFID printers. 0 = Reserved1 = EPC2 = TID (Tag ID)3 = UserDefault: E |
^XA ^RS8 ^RFW,A^FD00 my data^FS ^XZ
^XA ^RB96,8,3,3,20,24,38 ^RFW,E^FD16,3,5,78742,146165,1234567891^FS ^XZ
^XA ^RS8 ^RFW,H,3,4,1^FD11112222^FS ^XZ
^XA ^RS8 ^RFR,H,0,8,2^FN1^FS^HV1,,8-byte Tag ID Data:^FS ^XZ
^RFW,H,P^FD12345678,88887777^FS
^RFW,H,P^FD12345678^FS
^RFW,H,P^FD,88887777^FS
^RFW,H,,,A^FD1122334455667788^FS
^RFS,H,P^FD12345678^FS