Parameters | Details |
---|---|
a = condition type | Values: A = paper outB = ribbon outC = printhead over-tempD = printhead under-tempE = head openF = power supply over-tempG = ribbon-in warning (Direct Thermal Mode)H = rewind fullI = cut errorJ = printer pausedK = PQ job completedL = label readyM = head element outN = ZBI (Zebra BASIC Interpreter) runtime errorO = ZBI (Zebra BASIC Interpreter) forced errorQ = clean printheadR = media lowS = ribbon lowT = replace headU = battery lowV = RFID error (in RFID printers only)W = all errors (in RFID printers only)* = all errors (in non-RFID printers) |
b = destination | Values: A = serial portB = parallel portC = e-mail addressD = TCP/IPE = UDP/IPF = SNMP trap* = wild card to stop alerts for all destinations |
c = halt messages | Values: Y = halt messagesN = start messagesDefault: Y |