MP72 Scanner Only or MP72 Scale with Single Cable Protocol

MP72 Scanner Only or MP72 Scale with Single Cable Protocol

The RS-232 interface supports various host and auxiliary connections.
The MP72 uses +/-6V RS-232 signal levels to accommodate long cable lengths and increased noise immunity.
RS-232 Connections
Item
Description
1
12 VDC power
2
POS
3
RS-232 Aux 1
4
RS-232 Aux 2
Interface cables vary depending on configuration.
Host Connections
Port
Connection Options
POS
Standard USB (p/n CBA-U51-S16ZAR)
USB PlusPower (p/n CBA-U52-S16PAR)
RS-232 (p/n CBA-R51-S16ZAR)
RS-485 (p/n CBA-M51-S16PAR)
Auxiliary Connections
Configuration Choices for the Devices Below
RS-232 Device Port Configuration Value
4
Connect Device to These Ports
RS-232 AUX 1
RS-232 AUX 2
USB1 (AUX A)
USB2 (AUX B)
RS-232 auxiliary scanner, and a Sensormatic Controller
3
0
1
Sensormatic Controller
RS-232 auxiliary scanner
3
USB auxiliary scanner
3
USB auxiliary scanner
3
RS-232 auxiliary scanner, and a Dual Cable Scanner/Scale
1
Dual Cable Scanner/Scale
2
RS-232 auxiliary scanner
3
USB auxiliary scanner
3
USB auxiliary scanner
3
Dual Cable Scanner/Scale, and a Sensormatic Controller
3
2
Sensormatic Controller
Dual Cable Scanner/Scale
2
USB auxiliary scanner
3
USB auxiliary scanner
3
Third-Party-Scale & Sensormatic-Controller
4
Third-Party-Scale
Sensormatic Controller
USB auxiliary scanner
3
USB auxiliary scanner
3
1
Default setting
2
The Dual Cable Scanner/Scale supports the industry standard SASI, DIGI, ICL OMRON, ICL Old OMRON, ICL Portugal, and scale-only protocols. The default protocol on this Dual Cable Scanner/Scale port is SASI.
3