Pre-installation Notes

Pre-installation Notes

For an existing scale display from a previous scanner, place the Zebra Scale Display in the same location or a new location specified by the retailer and/or local weights and measures law.
Unscrew the existing display, disconnect the cable from the scanner, and remove the display and cables.
For a new Scale Display installation, determine the location based on counter design and viewing angle, where it cannot impede access to scanned items moving over the MP72, payment terminals, printer validation, paper roll slots, or access to replace consumables (rolls).
Ensure both the cashier and customer can see the weight value displayed.
Drill the required holes where the display is to be mounted.
  • The optional 19 mm (3/4 in.) diameter hole is used for cable pass-through.
    The cable can also be routed on top of the counter via the notch in the base of the display.
  • Use the display to mark holes for the mounting screws, and drill two pilot holes to a diameter of 2.4 mm (3/32 in.) and a depth of 25 mm (.98 in.)