User Interface Indications for Scale

User Interface Indications for Scale

This section defines LED and beeper indications for the scale.
Scale Related LED and Beeper Sequences
Scale State
7-segment Diagnostic Display
LED (System)
Beeper Sequence
Scale Zero Button (LED)
Optional Scale Display
Scale disabled
No change
No change
None
OFF
Blank
Scale normal - stable with weight
No change
No change
Solid Green
ON
Weight Reading
Under zero
No change
No change
None
Flashing
All “- - - - -” (dashes)
Over range condition (weight is greater than 30.09 lb or 15.045 kg)
No change
No change
None
OFF
EEEEE
Weight unstable
No change
No change
None
OFF
Numerical values blank but measurement unit icons (lb or kg) remain on.
Scale Zero button press
If zero operation fails it scrolls U12
Red (Warning) if zero operation fails on a Scale Zero button press; otherwise, no change
Click sound
No change
If successful weight reads 0 (zero) and <0> indicator icon illuminates.
Scale out of calibration
Scrolls fault code U14
Red (Warning)
None
OFF
Blinks CAL
Successfully entering scale legal Calibration Mode
Program Legal Parameters and Calibration at NO LOAD
Scrolls C00Lb OR C00g depending on units programmed as pounds (lb) or kilograms (kg)
Scrolls C25Lb or C11g depending on units programmed as pounds (lb) or kilograms (kg)
Any step - Calibration Fails - Scrolls fault code: u##
No change
Five long beeps
Off
Calibration at NO LOAD
Blinks between CAL00 and CAL_ _ with correct unit icon illuminated (lb or kg).
Blinks CAL25 with lb icon illuminated, or CAL11 with kg icon illuminated.
Blinks between CAL P (PASS) and CAL S (save legal parameter settings).
Any step - Calibration fails blinks CAL F.
Between calibration steps
No change
No change
No change
Off
Blinks HOLD while taking a measurement
Performing a calibration step
No change
No change
Single long beep after pressing the Scale Zero button
Off
No change
Failure to place the correct load on the scale at Calibration at LOAD
C25Lb or C11g depending on units programmed
No change
Two long beeps
No change
No change
Successfully executing and exiting a scale legal calibration
Calibration procedure semantics removed from display
No change
Three short beeps
Solid green on if weight stable after reset of scale
Scale is reset either by pressing the Scale Zero button, scanning the Scale Reset parameter barcode, or powering the unit OFF then ON. The seven segment test runs.
Cold reset of scale
No change
No change
No change
except at Calibration Success or Failure - Repeat scrolls of CALP then CALS - when the Scale Zero button is pressed three short beeps sound
No change
Seven segment test runs and displays:
  • 00.000 all icons illuminated for three seconds
  • Blank for one second
  • 99.999 all icons illuminated for three seconds
  • Blank for one second
  • Normal display
Audit Tally - Press and hold Scale Zero button for greater than three seconds when not in a Calibration Mode
Repeated scroll: C### then P### then #.##F
No change
None
No change
Blinks between C### and P### and #.##F
In Bootloader Mode
No change
Slow blinking red
Note: Do not turn off the system in this mode.
None
Off
Blinks LDG
Scale Error
Scrolls fault code: u##
Red (Warning)
None
Off
Blinks FAIL or blanks display with unit icon showing lb or kg illuminated.
Display can also blink CALF if the system was in a scale legal Calibration Mode.