rfid.reader_1.power.single_power

rfid.reader_1.power.single_power

This command sets the RFID reader power level for reading and writing to RFID tags for readers with a single power level.
This command applies only to the R110Xi HF printer, firmware version R65.X.

Setvar

To set the power level for reading and writing:
! U1 setvar "rfid.reader_1.power.single_power" "value"
Values
  • "high"
  • "medium"
  • "low"
Default
"low"

Getvar

To respond with the current power level:
! U1 getvar "rfid.reader_1.power.single_power"
This
setvar
example sets the antenna to high power for writing to RFID tags.
Example
! U1 setvar "rfid.reader_1.power.single_power" "high"
When the
setvar
value is set to
"high"
, the
getvar
result is
"high"
.