external_wired.ip.netmask

external_wired.ip.netmask

This setting refers to the external wired print server’s subnet mask address. This value is ignored if the IP protocol is not set to permanent.

Setvar

To instruct the printer to change the external wired print servers subnet mask:
! U1 setvar "external_wired.ip.netmask" "value"
Values
Any valid subnet mask.
Default
"255.255.255.0"

Getvar

To instruct the printer to respond with the external wired print server’s subnet mask:
! U1 getvar "external_wired.ip.netmask"
On SEH print server models PS102-Z or the PS105-Z, only the
getvar
command is supported.
Example
This
setvar
example shows the value set to
"255.255.255.0"
.
! U1 setvar "external_wired.ip.netmask" "255.255.255.0"
When the
setvar
value is set to
"255.255.255.0"
, the
getvar
result is
"255.255.255.0"
.