^JH

^JH

The
^JH
command configures the early warning messages that appear on the LCD.

Early Warning Settings

  • ZE500 series
  • Xi
    III,
    Xi
    III
    Plus
    , Xi4, RXi4
  • PAX
    3,
    PAX
    4
  • ZM400, ZM600, RZ400, RZ600
  • S4M
  • G-Series (“f” parameter only)
Format:
^JHa,b,c,d,e,f,g,h,i,j
Parameter
Details
a =
early warning media
a
= supplies warning (Xi4 and RXi4 printers only)
This parameter is for XiIIIPlus, Xi4, RXi4, PAX3, and PAX4 printers only.
Values:
E =
enable
D =
disable
Default:
D
b =
labels per roll
This parameter is for XiIIIPlus, PAX3, and PAX4 printers only.
Values:
100
to
9999
Default:
900
c =
media replaced
This parameter is for XiIIIPlus, PAX3, and PAX4 printers only.
Values:
Y =
yes
N =
no
Default:
N
d =
ribbon length
This parameter is for XiIIIPlus, PAX3, PAX4, and ZE500 printers only.
Values:
XiIIIPlus series printers:
N = 0M
0 =
100M
1 =
150M
2 =
200M
3 =
250M
4 =
300M
5 =
350M
6 =
400M
7 =
450M
PAX series printers:
N = 0M
0 =
100M
1 =
150M
2 =
200M
3 =
250M
4 =
300M
5 =
350M
6 =
400M
7 =
450M
10 =
600M
11 =
650M
12 =
700M
13 =
750M
14 =
800M
15 =
850M
16 =
900M
ZE500 series printers:
N = 0M
0 =
100M
1 =
150M
2 =
200M
3 =
250M
4 =
300M
5 =
350M
6 =
400M
7 =
450M
10 =
600M
Default:
1 - for 96XiIIIPlus
7 - for all other printers
e =
ribbon replaced
This parameter is for
Xi
III
Plus
,
PAX
3, and
PAX
4 printers only.
Values:
Y =
yes
N =
no
Default:
N
f =
early warning maintenance
This parameter is for Xi4, RXi4,
PAX
4, ZM400, ZM600, RZ400, RZ600, and S4M printers only.
Values:
E =
enabled
D =
disabled
Default:
D
On G-Series printers, this parameter must be enabled for the
^MA
driven system to work.
g =
head cleaning interval
Accepted value exceptions: accepted values for
Xi
III printer are 100M through 450M; accepted values for 600 dpi
Xi
III printers are 100M through 150M; accepted values for
PAX
4 series printers are up to 900M by increments of 50M; accepted values for ZM400/ZM600, RZ400/RZ600, and S4M printers are 0M through 450M.
Values:
0 =
100M
1 =
150M
2 =
200M
3 =
250M
4 =
300M
5 =
350M
6 =
400M
7 =
450M
8 =
500M
9 =
550M
10=
600M
11 =
650M
12 =
700M
13 =
750M
14 =
800M
15 =
850M
16 =
900M
Default:
1 - for 96XiIIIPlus
7 - for all other printers
h =
head clean
Values:
N =
No
Y =
Yes
Default:
N
i =
head life threshold
Values:
0 – 0 in or off100-3500000 in
Default:
1000000
j =
head replaced
Values:
N =
no
Y =
yes
Default:
N
Comments: